4Specifications
Terminal Parameter Parameter Details Specification
All terminals
Wiring terminal Maximum wire gauge, solid wire
1.5 mm
2
Maximum wire gauge, stranded
wire
1.0 mm
2
Cabling
Cable jacket diameter (
)
4-8 mm
Temperature sensor input
TEMP MOD
TEMP AMB
TEMP IR.
Sensor input Sensor type
3 x PT1000
3)
Nominal resistance/temperature
coefficient
3.85
/
o
C
Measurement range
-20
o
C - +100
o
C
Measurement accuracy
±
2
o
C
Short-circuit protection Yes
Electrical safety Direct contact protection Double/Reinforced insulation
Cabling Cable type
Single pair - 2-wire
1)
Maximum resistance per wire
2)
2
Irradiation sensor input
IR+
IR-
Sensor input Sensor type Current shunt (passive)
Measurement range 0 - 150 mV
Max. output impedance (sensor)
500
Input impedance (electronics)
24 k
Measurement accuracy ±5 % at 150 mV sensor output
voltage
Short-circuit protection Yes
Electrical safety Direct contact protection Double/Reinforced insulation
Cabling Cable type
Single pair - 2-wire
1)
Two pairs - 4 wires with temperature
compensation
Maximum resistance per wire
2)
10
Energy meter input
S0+
S0-
Sensor input Sensor type S0 output device
Sensor input class Class A
Nominal output current
12 mA for an 800
load
Maximum short-circuit output
current
24.5 mA
Open-circuit output voltage +12 VDC
Maximum pulse frequency 16.7 Hz
Short-circuit protection Yes
Electrical safety Direct contact protection Double/Reinforced insulation
Cabling Cable type
Single pair - 2-wire
1)
Maximum resistance per wire
2)
10
Relay output (normally open)
RELAY (NO)
Relay output Relay type Potential free contact
Rating AC 250 VAC maximum permitted voltage,
1.0 A, 230 W
Rating DC 24 VDC, 1.0 A, 24 W
Electrical safety Overvoltage category Class III
Cabling Cable type
Single pair - 2-wire
1)
Table 4.1 Sensor Interface Specifications
1)
Shielded or unshielded cables may be used.
2)
Cable resistances will result in a measurement offset.
3)
3
rd
input is used for compensation of the irradiation sensor.
Specifications